+2 votes
in Mathematics by kratos

A reversible heat pump uses 1 kW of power input to heat a 78 F room, drawing energy from the outside at 60 F. Assume every process is reversible what are the total rates of entropy into the heat pump from the outside and from the heat pump to the room?

1 Answer

+4 votes
by kratos
 
Best answer

Since the process was assumed reversible the two fluxes are the same.

...